微信公众号

官网二维码

中国癌症防治杂志 ›› 2019, Vol. 11 ›› Issue (5): 421-425.doi: 10.3969/j.issn.1674-5671.2019.05.12

• 临床应用 • 上一篇    下一篇

个性化容积旋转调强准直器角度优化在宫颈癌放疗中的应用

  

  • 出版日期:2019-10-25 发布日期:2019-11-26
  • 通讯作者: 童肖广 E-mail:hgmf91705@163.com

Application of personalized volumetric modulated arc therapy collimator angle optimization in cervical cancer radiotherapy

  • Online:2019-10-25 Published:2019-11-26

摘要: 目的 探讨个性化容积旋转调强准直器角度优化在宫颈癌放疗中的应用效果。方法 选取10例宫颈癌患者并分别设计VMATapt和VMAT20计划。其中,VMATapt计划全弧随机分成3个段弧,根据不同机架角度下靶区的投影形状,并基于最小面积法计算最优的分段方式和每段弧的最优准直器角度;VMAT20计划为常规设计,准直器角度为20°。比较两种计划的平均钨门面积,靶区和危及器官的剂量学参数,机器总跳数(monitor units,MUs)以及靶区外2 cm (PTV+2 cm)的平均剂量。结果 VMATapt计划的平均坞门面积小于VMAT20计划[(18.5±0.7) cm2 vs (20.2±0.9) cm2P<0.001]。VMATapt计划的靶区均匀性指数优于VMAT20计划[(0.05±0.02) vs (0.06±0.01),P=0.001],MUs和靶区外PTV+2 cm区域平均剂量低于VMAT20计划(P<0.05)。两种计划PTV参数、危及器官参数、适形指数比较差异均无统计学意义(P>0.05)。结论 采用个性化容积旋转调强准直器角度优化方法设计VMATapt计划能满足宫颈癌患者处方剂量要求,且较VMAT20计划可提高靶区均匀性,降低机器总跳数和靶区外PTV+2 cm区域剂量。

关键词: 宫颈癌, 容积旋转调强, 准直器, 放射治疗

Abstract: Objective To explore the application effect of personalized volumetric modulated arc therapy collimator angle optimization in cervical cancer radiotherapy. Methods Ten patients with cervical cancer were selected and VMATapt and VMAT20 plans were designed. The VMATapt was randomly divided into three section arcs. According to the projection of the PTV at different gantry angles and based on the minimum field sizes,the optimal segmentation mode and the optimal collimator angle for each section of the arc were calculated in the VMATapt plan. The VMAT20 was planned for a conventional design with a collimator angle of 20°. Compared the averaged Jaw size,the dosimetric parameters of the target area and endangered organs,the machine units(MUs),and the average dose of 2 cm outside the target area(PTV+2 cm) between the two plans. Results Compared with the VMAT20 plan,the averaged Jaw size of VMATapt plan was smaller[(20.2±0.9) cm2 vs (18.5±0.7) cm2P<0.001],homogeneity index was better[(0.06±0.01) vs (0.05±0.02),P=0.001],MUs and PTV+2 cm were lower(P<0.05). However,there were no significant differences in PTV parameters,organ parameters,and conformal index value between the two plans(P>0.05). Conclusion VMATapt plan can meet the prescription dose requirements of patients with cervical cancer by using the personalized volumetric modulated arc therapy collimator angle optimization method,and improve the target uniformity and reduce the machine units and PTV+2 cm outside the target area compared to the VMAT20 plan,which can be used for cervical cancer VMAT design.

Key words: Cervical cancer, Volumetric modulated arc therapy, Collimator angle, Radiotherapy

中图分类号: 

  • R737.33